Valid license from HP required for possession, use or copying. Consistent with FAR 12.21 1 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. Intended audience This guide is intended for storage system administrators.HP P2000 G3 SAS MSA System User Guide. Features and benefits Product features and supported options are subject to change. Online documentation describes the latest product and product family characteristics, including currently supported features, options, technical specifications, configuration data, related optional software, and product warranty information. The controller module face plate is enlarged to show relevant detail. P2000 G3 SAS MSA System controller module face plate. Drive enclosures supported by the P2000 G3 MSA System controllers are described in the following sections. The 3Gb drive enclosures supported by the newer controller enclosures are listed for customers upgrading existing legacy systems. The super-capacitor pack provides energy for backing up unwritten data in the write cache to the CompactFlash in the event of a power failure. P2000 G3 MSA System controller to drive enclosure cabling is described within this chapter. Cabling of 3Gb drive enclosures to newer 6Gb controllers is addressed for customers upgrading existing legacy systems. Do not install an HP P2000 G3 FC MSA System and HP P2000 G3 SAS MSA System controller module in the same chassis. IMPORTANT: Connecting 3Gb and 6Gb drive enclosures limits performance and should be done only when upgrading legacy product configurations. HP P2000 G3 SAS MSA System User Guide. Controller A Controller B Figure 6 Fault-tolerant cabling: P2000 G3 controllers and P2000 6Gb drive enclosures The diagram above shows a dual-controller enclosure cabled to P2000 6Gb drive enclosures featuring dual-expansion modules.http://genius.pskovedu.ru/site/htmlimages/mitsubishi-ducted-air-conditioning-manual.xml
The diagram at left shows a dual-controller enclosure cabled to D2700 6Gb drive enclosures featuring dual-expansion modules. IMPORTANT: For comprehensive configuration options and associated illustrations, refer to the HP P2000 G3 MSA System Cable Configuration Guide. Installing the enclosures. SAS host ports The P2000 G3 SAS MSA System controller modules use the Serial Attached SCSI (Small Computer System Interface) interface protocol for host port connection, featuring either one or two controller modules. Each. Connect an RJ-45 Ethernet cable to the network management port on each P2000 G3 MSA System controller. Connect the other end of each Ethernet cable to a network that your management host can access (preferably on the same subnet). This port differs from G1 and G2 controllers. Use Autorun or manually start the CD. The MSA Device Discovery Tool will run. HP P2000 G3 SAS MSA System User Guide. The Getting Started section provides instructions for signing-in to SMU, introduces key concepts, addresses browser setup, and provides tips for using the main window and the help window. If you encounter problems communicating with the port after cabling your computer to the USB device, you may need to either download a device driver (Windows), or set appropriate parameters via an operating system command (Linux). HP P2000 G3 SAS MSA System User Guide. Answer Possible reasons Actions System functioning properly.In dual controller configurations, there is no need to transport a failed controller’s cache to a replacement controller because the cache is duplicated between the peer controllers. HP P2000 G3 SAS MSA System User Guide. Failure to use this procedure will result in the loss of data stored in the cache module. HP P2000 G3 SAS MSA System User Guide. Sequential enclosure ID numbering of controller enclosures begins with the integer 1. The drive is online, but it is not currently active. The fault may involve metadata on the disk rather than the disk itself.http://cptcla.org/userfiles/mitsubishi-eclipse-1992-service-repair-manual.xml
See the Clearing disk metadata topic in the SMU reference guide or online help. Rear panel LEDs P2000 G3 SAS MSA System SFF and P2000 G3 SAS MSA System LFF 4 5 6 (Typical) IMPORTANT: Early versions of the P2000 G3 MSA System controller modules show network port LED labels in reversed position: LINK is shown on the left and ACT is shown on the right. On such units, the LED labeled LINK reports ACT behavior and the LED labeled ACT reports LINK behavior. MSA70 3Gb drive enclosure A P2000 G3 MSA System controller can also be attached to an MSA70 3Gb drive enclosure running firmware version 2.18 or later. For information about the MSA70 3Gb drive enclosure, including detailed. Unit Locator Off — Normal operation. Blinking white— Physically identifies the expansion module. SAS In Port Status Green —. AC model DC model Table 18 LEDs — HP P2000 G3 MSA System power supply units — rear panel Description Definition Input Source Power Good Green — Power is on and input voltage is normal. HP P2000 G3 SAS MSA System User Guide. However, one person can safely lift an enclosure if its weight is reduced by removing the power supply modules and disk drive modules. Table 20 provides weight data for P2000 G3 controller enclosures and select drive enclosures. For information about other HP MSA drive enclosures that may be cabled to these systems (e.g., MSA70 or D2700), check Quickspecs, which can be found from your HP MSA products page HP P2000 G3 SAS MSA System User Guide. For more information on static electricity or assistance with product installation, contact an authorized reseller. HP P2000 G3 SAS MSA System User Guide. Tasks in this docu- Openings must be Leave modules Keep parts in electrostatic containers Removing a module from an operational enclosure significantly changes air flow within the enclosure. For information about a specific host (IDs, names, and mappings): In the Configuration View panel, expand the display under Hosts and then select a specific host.
Insert the CompactFlash that you removed from the failed controller Pull the module straight out of the enclosure (3). If the firmware versions differ HP support: between the two controllers, Partner Firmware Upgrade. If a dedicated spare or global spare of the proper type and size is present, that spare is used to automatically reconstruct the vdisk; events 9 and 37 are logged to indicate this. If no usable spare disk is present, but an available disk of the proper type and size is present and the dynamic spares feature is enabled, that disk is used to automatically reconstruct the vdisk; event 37 is logged. Recommended Action: - If no spare is present and the dynamic spares feature is disabled (that is, event 37 is NOT logged), configure an available disk as a dedicated spare for the vdisk or replace the failed disk and configure the new disk as a dedicated spare for the vdisk. That spare is used to automatically reconstruct the vdisk; confirm this by checking that events 9 and 37 are logged. - Otherwise, reconstruction automatically starts and event 37 is logged. Replace the failed disk and configure the replacement as a dedicated or global spare for future use. - If the replacement disk was previously used in another vdisk and has a status of leftover (LEFTOVR), clear the disk's metadata so you can assign the disk as a spare. - Confirm that all failed disks have been replaced and that there are sufficient spare disks configured for future use. 2015-03-31 02:29:09 A4863 8 A disk that was part of a vdisk is down. Click here to get file. Hewlett packard storage enclosure ap843b. HP StorageWorks Modular Smart Array manuals. Modular Smart Array Service port (used by service personnel only) MSA70 3Gb drive enclosure P2000 G3 MSA System controllers can also be attached to an MSA70 3Gb drive HP StorageWorks P2000 G3 Modular Smart Array Controller Module P2000 Controller pdf manual download.Consistent with HP P2000 G3 MSA System SMU Reference Guide.
3 Subscription service. They are ideal for companies with small budgets or limited IT expertise, and also larger companies with departmental or remote requirements. Each solution is designed to be easy to deploy, to be secure, along with low management costs, while driving rapid return on investment through efficient storage consolidation. The MSA P2000 G3 arrays are 2U storage area network (SAN) or direct connect solutions (OS and protocol dependent) offering a choice of five controllers - two FC, one SAS, one 10GbE iSCSI and the newest model features a four port 1 Gb iSCSI. The first Fibre Channel controller is a high-performance, 8 Gb dual port model. The second offering is a unique dual-purpose Combo controller with two 8 Gb Fibre Channel ports with the addition of two 1GbE iSCSI ports. The third controller choice is 6Gb SAS with four ports per controller. There is also the addition of a two port 10 Gb iSCSI, while the latest controller introduction features four 1 Gb iSCSI ports per controller. Whatever the situation calls for, the P2000 G3 line-up has the right solution. The 8 Gb FC ports support a full FC SAN while the two 1GbE iSCSI ports can serve two purposes. With this combination you can economically share the array storage resource with a smaller department accessing it over iSCSI or enable the new optional Remote Snap functionality over iSCSI protocol (also available over FC). The MSA P2000 G3 SAS is the follow-on product to the MSA2000sa G2, adding the latest 6 Gb SAS technology to the four host ports per controller. The P2000 G3 SAS array is designed for directly attaching up to four dual-path or eight single path rack servers. SAS array support for BladeSystems utilizes the HP 6 Gb SAS BL Switch. The MSA P2000 G3 10GbE iSCSI brings the very latest in high-performance host connection with technology generally found only in higher priced arrays.
The bandwidth it provides in conjunction with server consolidation is highly advantageous in shared storage configurations. Array connection to 10GbE switches that are in turn connected to 1GbE NICs is commonplace. Directly attached server support requires the server units to have 10GbE NICs. Rounding out the controller choices is the MSA P2000 G3 iSCSI controller featuring four 1Gb iSCSI Ethernet ports, double the number of the G2 model. This allows an array that keeps the price of the components, particularly the interconnects, low while markedly increasing the performance capabilities. All MSA P2000 G3 models can be equipped with single or dual controllers, feature the same scalability, and offer 6 Gb SAS back-end transmission speed to drives and JBODs. Significant data protection advances are delivered by the all P2000 G3 arrays. All G3 units come STANDARD with sixty-four snapshot capability at no extra cost and there is an option for the G3 series of five hundred and twelve snapshots. Volume Copy (clone) also comes standard. Hot add of expansion enclosures is also supported. The controller-less MSA P2000 chassis is offered in two models - one comes standard with twelve Large Form Factor (LFF) 3.5-inch drive bays, the other can accommodate twenty-four Small Form Factor (SFF) 2.5-inch drives. Both are able to simultaneously support enterprise-class SAS drives, SAS Midline, and archival-class SATA Midline drives. Either chassis can have one or two matching P2000 G3 controllers (same protocol) and are available with AC or DC power Supplies. The HP modular approach to entry level SAN solutions enables incremental customer purchases, allowing the array to grow as needs grow, thus allowing a maximum return on investment. Choose a single controller unit for low initial cost with the ability to upgrade later; or decide on a model with dual controllers for the most demanding entry-level situations.
There are no unexpected additional charges, licenses or fees as you add enclosures or hosts and users. QuickSpecs HP MSA P2000 G3 Modular Smart Array Systems Overview DA - 13551 North America — Version 36 — December 9, 2013 Page 1 Next. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with Hp P2000 Manual. To get started finding Hp P2000 Manual, you are right to find our website which has a comprehensive collection of manuals listed. Our library is the biggest of these that have literally hundreds of thousands of different products represented. I get my most wanted eBook Many thanks If there is a survey it only takes 5 minutes, try any survey which works for you. Please check your inbox, and if you can’t find it, check your spam folder to make sure it didn't end up there. Please also check your spam folder. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. UNIX is a registered trademark of The Open Group. Racks may become unstable if more than one component is extended. If a CSR part needs replacing, HP ships the part directly to you so that you can install it at your convenience. Some parts do not qualify for CSR. Your HP-authorized service provider will determine whether a repair can be accomplished by CSR.
For North America, see the CSR website: Online documentation describes the latest product and product family characteristics, including currently supported features, options, technical specifications, configuration data, related optional software, and product warranty information. The controller module face plate is enlarged to show relevant detail. Drive enclosures supported by the P2000 G3 MSA System controllers are described in the following sections. The 3Gb drive enclosures supported by the newer controller enclosures are listed for customers upgrading existing legacy systems. For information about P2000 G3 MSA System products, visit.The controller writes user data in the cache memory on the module rather than directly to the drives. The controller detects sequential array access, reads ahead into the next sequence of data, and stores the data in the read-ahead cache. Then, if the next read access is for cached data, the controller immediately loads the data into the system memory, avoiding the latency of a disk access. These data are then written to disk after the issue is corrected. To protect against writing incomplete data to disk, the image stored on the CompactFlash is verified before committing to disk. Failure to use this procedure will result in the loss of data stored in the cache module. The CompactFlash must stay with the same enclosure.The super-capacitor pack provides energy for backing up unwritten data in the write cache to the CompactFlash in the event of a power failure. Unwritten data in CompactFlash memory are automatically committed to disk media when power is restored.To ensure a successful installation, perform the tasks in the order they are presented. See the SMU reference guide or online help for additional information. See the SMU reference guide for additional information. Cabling of 3Gb drive enclosures to newer 6Gb controllers is addressed for customers upgrading existing legacy systems.
You can also configure drive enclosures of mixed type, as shown in Table 3 on page 26. Reverse cabling allows any drive enclosure to fail — or be removed — while maintaining access to other enclosures. Fault tolerance and performance requirements determine whether to optimize the configuration for high availability or high performance when cabling. P2000 G3 MSA System controller enclosures support both 3Gbps and 6Gbps internal disk drive speeds, together with 3Gbps and 6Gbps expander link speeds. Controller and expansion modules are identified by. When connecting multiple drive enclosures, use reverse cabling to ensure the highest level of fault tolerance. Controller module 1B is connected to the lower expansion module (5B) of the last drive enclosure, with connections moving in the opposite (reverse) direction (green). Hot-add of drive enclosures is also supported. If you connect a 3Gb drive enclosure to a 6Gb controller enclosure, data throughput occurs at the drive enclosure’s 3Gbps data rate (see Figure 4 on page 28). For a current list of supported cables, check the MSA2000 G2 Quickspecs located on the HP MSA products page at. Select your product. Quickspecs links are located on the right. Components are labeled with back-end SAS data rates and other relevant attributes. Simplified IOM face plates are shown. Table 4 on page 27 provides details for cabling expansion modules. Do not install an HP P2000 G3 FC MSA System and HP P2000 G3 SAS MSA System controller module in the same chassis. However, when cabling supported drive enclosures of mixed type, consider the following factors regarding components equipped with SAS2.0 and SAS1.1 expanders (labeled in Figure 1 on page 25). Do not mix 6Gb and 3Gb disk drives in the same enclosure. A 6Gb drive enclosure will perform at a 3Gbps data transfer rate if cabled after a 3Gb drive enclosure. Consistent with FAR 12.211 and 12.
212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice. Intended audience This guide is intended for storage system administrators. Page 12 Document conventions and symbols Document conventions Table 1 Convention Element Medium blue text: Figure 1 Cross-reference links and e-mail addresses Medium blue, underlined text ( Page 13 Rack stability WARNING. Racks may become unstable if more than one component is extended. Page 15 1 Overview The HP P2000 G3 SAS MSA System is a high-performance storage solution combining outstanding performance with high reliability, availability, flexibility, and manageability. Features and benefits Product features and supported options are subject to change. Online documentation describes the latest product and product family characteristics, including currently supported features, options, technical specifications, configuration data, related optional software, and product warranty information. The controller module face plate is enlarged to show relevant detail. Transportable CompactFlash During a power loss or array controller failure, data stored in cache are saved off to non-volatile memory (CompactFlash). These data are then written to disk after the issue is corrected. To protect against writing incomplete data to disk, the image stored on the CompactFlash is verified before committing to disk. Page 22 Components Page 23 3 Installing the enclosures Installation checklist The following table outlines the steps required to install the enclosures and initially configure the system. To ensure a successful installation, perform the tasks in the order they are presented. Table 2 Installation checklist Step Task Where to find procedure 1. Install the controller enclosure and optional drive enclosures in the rack, and attach ear caps.
You can also configure drive enclosures of mixed type, as shown in Table 3 on page 26. The firmware supports both straight-through and reverse SAS cabling. Page 25 Connecting controller and mixed drive enclosures P2000 G3 MSA System controller modules support cabling of 3Gb and 6Gb SAS link-rate LFF and SFF expansion modules — in mixed fashion — as shown in Figure 10 on page 32, and as further described in Additional cabling considerations (below); the HP P2000 G3 MSA System Cable Configuration Guide; and HP white papers (listed on the following page). For detailed illustrations showing all components, see Rear panel components on page 19. Page 29 Controller A 1A Controller B 1B 2A 2B In Out In Out Figure 5 Cabling connections between P2000 G3 controllers and an MSA70 3Gb drive enclosure The diagram above shows dual-controller modules connected to dual-expansion modules. Plug the other end of the power cord into the rack power source. Wait several seconds to allow the disks to spin up. Repeat this sequence for each PSU within each drive enclosure. 3. Plug the power cord into the power cord connector on the back of the controller enclosure (see Figure 11). Page 35 DC model Locate the two DC power cables provided with your controller enclosure. TIP: See the HP MSA System VDS and VSS Hardware Providers Installation Guide and HP MSA System MPIO DSM Installation Guide to aid in planning and implementing your MPIO DSM installation. SAS host ports connect to SAS hosts or switches; they are not used for replication. Connecting direct attach configurations P2000 G3 SAS MSA System LFF and P2000 G3 SAS MSA System SFF support up to eight direct-connect server connections, four per controller module. Page 40 Connecting hosts Page 41 5 Connecting to the controller CLI port Device description P2000 G3 MSA System controllers feature a new command-line interface (CLI) port used to cable directly to the controller and initially set IP addresses, or perform other configuration tasks.
The MSA Device Discovery Tool will run. 4. Follow the instructions to discover the IP addresses of the controller or controllers. Record these IP addresses so that you can specify them whenever you manage the controllers using SMU or the CLI. Once you have successfully completed steps 1 through 8 therein, you can access the management interface using your web-browser. Accessing SMU Upon completing the hardware installation, you can access the controller module’s web-based management interface, SMU (Storage Management Utility), to monitor and manage the storage system. Page 46 Basic operation Page 47 7 Troubleshooting CLI port connection P2000 G3 MSA System controllers feature a new CLI port employing a mini-USB Type B form factor. If you encounter problems communicating with the port after cabling your computer to the USB device, you may need to either download a device driver (Windows), or set appropriate parameters via an operating system command (Linux). See Connecting to the controller CLI port for more information. Page 48 If the enclosure does not initialize It may take up to two minutes for the enclosures to initialize. Correcting enclosure IDs When installing a system with drive enclosures attached, the enclosure IDs might not agree with the physical cabling order. Page 49 Is the controller back panel OK LED off. Answer Possible reasons Actions No System functioning properly. Page 50 Is a connected host port’s Host Link Status LED off. If possible, test with another port. Page 51 Is the power supply’s Input Power Source LED off. Answer Actions No, the Cache LED status is off, and the controller does not boot. If valid data is thought to be in Flash, see Transporting cache; otherwise, replace the controller. No, the Cache Status LED is off, and the controller boots. The system is flushing data to disks. If the problem persists, replace the controller. Yes, at a strobe 1:10 rate - 1 Hz, and the controller does not boot. See Transporting cache.
Page 53 This step isolates the problem to the external data path (host cable and host-side devices) or to the controller module port. Return the cable to the original port. If the link status LED remains off, you have isolated the fault to the controller module’s port. Resolving voltage and temperature warnings 1. Page 55 Temperature sensors Extreme high and low temperatures can cause significant damage if they go unnoticed. Each controller module has six temperature sensors. Of these, if the CPU or FPGA (Field Programmable Gate Array) temperature reaches a shutdown value, the controller module is automatically shut down. Each power supply has one temperature sensor. When a temperature fault is reported, it must be remedied as quickly as possible to avoid system damage. Page 56 Troubleshooting Page 57 A LED descriptions Front panel LEDs Left ear Right ear P2000 4 7 10 3 6 9 12 1 4 1 2 3 5 6 Left ear Right ear P2000 4 1 2 3 5 6 Table 12 LEDs — HP P2000 G3 MSA Systems controller enclosure front panels LED Description Definition 1 Enclosure ID Green — On Enables you to correlate the enclosure with logical views presented by management software. The drive is online, but it is not currently active. Blinking irregularly Off The drive is active and operating normally. Removing a drive may terminate the current operation and cause data loss. The drive is rebuilding. Off 1 Off Either there is no power, the drive is offline, or the drive is not configured. The fault may involve metadata on the disk rather than the disk itself. Page 60 LEDs — HP P2000 G3 SAS MSA System LFF and SFF rear panel Table 15 LED Description Definition 9 Cache Status Green — Cache is dirty (contains unwritten data) and operation is normal. Off — In a working controller, cache is clean (contains no unwritten data). Blinking green — A CompactFlash flush or cache self-refresh is in progress.P2000 6Gb 3. Page 62 MSA2000 3Gb 3.
5” 12-drive enclosure 1 2 1 0 0 3 4 5 6 7 Table 17 LEDs — HP MSA2000 3Gb rear panel 62 LED Description Definition 1 Power supply LEDs See Power supply LEDs on page 63. 2 Unit Locator Off — Normal operation. Blinking white— Physically identifies the expansion module. 3 SAS In Port Status Green — Port link is up and connected. Off — Port is empty or link is down. 4 OK to Remove Not implemented. Page 63 Power supply LEDs Power redundancy is achieved through two independent load-sharing power supplies. In the event of a power supply failure, or the failure of the power source, the storage system can operate continuously on a single power supply. Greater redundancy can be achieved by connecting the power supplies to separate circuits. DC power supplies are equipped with a power switch. AC power supplies may or may not have a power switch (model shown below has no power switch). Page 64 LED descriptions Page 65 B Environmental requirements and specifications Safety requirements Install the system in accordance with the local safety codes and regulations at the facility site. Follow all cautions and instructions marked on the equipment. Also, refer to the documentation included with your product’s ship kit. Site requirements and guidelines The following sections provide requirements and guidelines that you must address when preparing your site for the installation. Always install and operate the enclosures in a horizontal orientation. Physical requirements The floor space at the installation site must be strong enough to support the combined weight of the rack, controller enclosures, drive enclosures (expansion), and any additional equipment. Page 69 Power cord requirements Each enclosure equipped with AC power supply modules requires two AC power cords that are appropriate for use in a typical outlet in the destination country. Each power cord connects one of the power supply modules to an independent, external power source.
To ensure power redundancy, connect the two suitable power cords to two separate circuits; for example, to one commercial circuit and one uninterruptible power source (UPS). Page 70 Environmental requirements and specifications Page 71 C Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device. Checking your browser before accessing This process is automatic. Your browser will redirect to your requested content shortly. You may have to register before you can post: click the register link above to proceed. To start viewing messages, select the forum that you want to visit from the selection below. Web Browser support The P2000 G3 and the older MSA2000 support target based management, and include a Web interface and a telnet interface, and require a web browser for management. The P2000 G3 array allows this first copy to take place locally. Each ship with two.5m mini-SAS to mini-SAS cables. Imagine that this responsive data-sheet is included in the product page of your webshop. How to integrate Icecat LIVE JavaScript. Product name is a key part of the Icecat product title on a product data-sheet. Please contact your account manager at Icecat. In contrast, HP's new StorageWorks P2000 G2 arrays are designed so you can start small to keep costs down and grow. HP offers an excellent range of controller choices, expansion potential is very high and the price includes snapshots and vo. Icecat can be of assistance in securing the necessary permissions or implementing a brand's Digital Rights Management policies. Login to view all product specs or request a Full Icecat subscription to download product specs.